Water chiller classification

Sep 11, 2025

Leave a message

Water chillers are broadly categorized into stand-alone and immersion water chillers. Stand-alone water chillers are equipped with their own water pump and can operate independently of the main unit's water tank, connected via inlet/outlet pipes. Immersion water chillers, on the other hand, do not have a water pump and must be installed above the main unit's water tank, with the copper tubing at the bottom of the chiller submerged in the tank water.

 

The primary function of a water chiller is to cool the liquid water within the main unit, maintaining it within a specific temperature range.

 

A water chiller mainly consists of a refrigeration system, a water circuit system, and a control system. The refrigeration system comprises one or two independent compressor refrigeration systems. Each compressor refrigeration system includes a compressor, condenser, condenser fan, thermal expansion valve, plate heat exchanger, and refrigerant piping.

 

The water chiller uses R22 forced cooling and has an independent circulating water pump that draws water from the external water tank and sends it to the plate heat exchanger within the refrigeration system for cooling before returning it to the tank for continuous circulation.

 

LSD water chillers are equipped with high/low pressure protection, water pump/compressor overload protection and short circuit protection, power phase sequence/phase loss protection, compressor start-up delay protection, etc. In addition, water filters, pressure relays, water flow switches or overheat protection can be added according to usage needs.